X1Y1 safety capacitor

Category:Y capacitor

Keywords:Dongguan Zhenjia Electronic Technology Co., Ltd.

Click rate:

Release time:2019-11-11 09:08:36

Brief introduction:X1Y1 safety capacitor

Service hotline:13528595886

consultation
Product detail

X1Y1 safety capacitor:

Insulation class: reinforced insulation
Dielectric strength: 4000V

characteristic:

Ceramic dielectric with high dielectric constant

Flame retardant epoxy package

Passed CQC, VDE, ENEC, CK, UL safety certification standards

 

application:

① Power supply circuit noise suppression circuit for electronic equipment
② Suitable for AC line filter and AC adapter primary-secondary coupling
③ Switching power supply, electronic ballast, LED power supply

X and Y capacitors are safety capacitors. The difference is that X capacitors are connected at both ends of the input line to eliminate differential mode interference, and Y capacitors are connected between the input and ground lines to eliminate common mode interference;

X capacitors use plastic-sealed high-voltage CBB capacitors. CBB capacitors not only have better electrical performance, but also are connected in parallel with the input of the power supply to effectively reduce the impact of high-frequency pulses on the switching power supply.

Y capacitors --- there are high-voltage porcelain. The Y-type capacitor is connected between the phase line and the ground line. In order to not exceed the allowable leakage value of the ground wire defined by the relevant safety standards, the value of these capacitors is about a few nF. Generally, the Y capacitor should be connected to the wire with large noise interference;

The Y capacitor is divided into a Y1 capacitor and a Y2 capacitor. Y1 is a double-insulated Y capacitor and is used to bridge the primary and secondary sides. Y2 is a basic single-insulated Y capacitor and is used to bridge the primary side to protect the ground, that is, the FG line.

Safety capacitors are used in situations where the capacitor will not cause an electric shock after it fails, and will not endanger personal safety.

X Safety Capacitor Safety Level Allowable peak pulse voltage in application Overvoltage level (IEC664)

X1> 2.5kV ≤4.0kV SW {{

X2 ≤2.5kV IY-F 6bXV

X3 ≤1.2kV} _. T.S @; 9e

Y safety capacitor safety level insulation type rated voltage range

Y1 double insulation or reinforced insulation ≥ 250V

Y2 basic insulation or additional insulation ≥150V ≤250V

Y3 basic insulation or additional insulation ≥150V ≤250V

Y4 basic or supplementary insulation <150V

X capacitor suppresses differential mode interference

Y capacitor suppresses common mode interference

According to IEC 60384-14, capacitors are divided into X capacitors and Y capacitors.

1. X capacitance is the capacitor across L-N.

2. Y capacitor is the capacitor across L-G / N-G. (L = Line, N = Neutral, G = Ground).

(1.) The most important purpose of adding Y-CAP is to overcome EMI

(2.) Now most people don't want to add Y-CAP, there are two points:

a. In order to reduce costs, a Y-CAP has 0.3RMB. Now everyone is working on NO Y design.

b. Our switching power supply has a lot of troubles when used on some audio equipment. For example, the switching power supply for mp3 is not as good as the linear power supply. For fixed telephones, the switching power supply for ADSL will have noise;

3. The safety regulations did not say that the Y-CAP must be added, as long as your EMI can pass, too much Y-CAP will affect the leakage current.

X capacitors are divided into X1, X2, X3. The main differences are: 1. X1 withstands high voltages greater than 2.5 kV, 4 kV or less, 2. X2 withstands high voltages less than or equal to 2.5 kV, 3. X3 withstands high voltages less than or equal to 1.2 kV For Y1, Y2, Y3, Y4, the main differences are: 1. Y1 withstands high voltages greater than 8 kV, 2. Y2 withstands high voltages greater than 5 kV, 3. Y3 withstands high voltages n / a 4. Y4 withstands high voltages greater than 2.5 kV. Then "X1 400V, Y1 250V" means that the parameters when used as X capacitors are: withstand voltage greater than 2.5KV, the maximum operating voltage should not exceed 400V; the parameters when used as Y capacitors are: withstand voltage greater than 8KV, the maximum operating voltage should not exceed 250V. So you can choose the right capacitor yourself.

The safety capacitor 250V can replace the high-voltage ceramic capacitor 3KV. However, high-voltage ceramic capacitors cannot replace safety capacitors because there is no safety certification.

previous:没有了

next:X1Y2 safety capacitor

Dongguan Zhenjia Electronic Technology Co., Ltd.

Company address :No. 35, Guiyuan Second Road, Hanxi Water Village, Chashan Town, Dongguan City

Company address :Tongzheng Xi Lu, Yulin City, Guangxi

Web site :en.dg-zhenjia.com

Telephonic:13528595886

Mobile phone:135-2859-5886 Mr. Liu

E-mail :zhenjiafactory@163.com

Mobile phone:135-5972-1396 Ms. Wu

Tell the truth:86-0769-82970719

Business QQ :2942869774  Ms. Wu

技术支持:金站网

Wechat ID

粤ICP备19137036号

粤公网安备 44190045345345402003559号

Technical Support:Dongguan website construction
 

Online consultation

在线客服

WeChat ID

QQ chat

Contact WeChat

E-mail:

zhenjiafactory@163.com

Telephonic:

135-2859-5886

135-5972-1396